SEAGATE e - Storage enclosure - 106 bays (SAS-3) - HDD - rack-mountable - 4U
|
|
SEAGATE e - Storage enclosure - 106 bays (SAS-3) - HDD - rack-mountable - 4U
-
Disk Interface
SAS
-
Installed
2120TB
-
Max Disks
106
-
RAID
Yes
-
Type
Rack (4U)
-
Disk Size
3.5"
|
Exos E 4U106
Features:
- Scale your data centre with this very high density storage platform
- Minimise a data centre’s footprint and power consumption while maximising storage space
- Eliminate efficiency-draining acoustic interference with the proprietary noise attenuator
- Maintain your data centre easily with toolless drive carriers that save hours of time
- Ensure data is constantly available with hot-swappable controllers, PSUs, system fan modules, drives, and expander cards
Specifications:
General
- Max TB Per Chassis 2332 TB, Using Qty 106, 22 TB 3.5” SAS Drives
- Redundant Path Yes (SAS only)
- Host/Expansion I/O Ports Four ×4 mini-SAS HD Expansion I/O connectors per I/O module
- Management/Status Reporting In-band SCSI Enclosure Services
- Device Support SAS and SATA device support, up to 2.5 PB raw capacity with 24 TB SAS drives
- Max Drives per Enclosure 106 (for a full list of supported drives, please contact your account or sales manager)
- Hot-Swappable Components Hard drives, power supply units (PSUs), cooling modules, side-plane expanders, and I/O modules
- Physical Height (with top cover): 176.4 mm/6.95 in | Width (without ears and rails): 441 mm/17.4 in | Depth (with handles, without cables): 1139
- mm/44.8 in | Weight 45 kg / 99 lb | Weight (with drives): 141 kg/310 lb
Power Requirements
- Input Power Requirements 200VAC-240VAC, 50Hz/60Hz
- Max Power Output per PSU 2000W
Environmental/Temperature Ranges
- Operating/Non-operating Altitude –100 m to 3,000 m (–330 ft to 10,000 ft) / –100 m to 12,192 m (–330 ft to 40,000 ft)
- Operating/Non-operating Temperature ASHRAE A2, 5°C to 35°C (41°F to 95°F) derate 1°C for every 300m above 900m / –40°C to +70°C (–40°F to +158°F)
- Operating/Non-operating Humidity –12°C DP and 8% RH to 21°C DP and 80% RH, Max DP 21°C, Max rate of change (°C/hr): 5/20/5% to 100% non-condensing
- Operating/Non-operating Shock2 3 Gs, 11 ms (per axis) / 15 Gs, 7 ms, 10 shock pulse
- Operating/Non-operating Vibration3 0.18 Gs rms, 5Hz to 500Hz, 30 min per axis / 0.54 Gs rms (in Z) 0.25 Gs rms (in X & Y), 6Hz to 200Hz
Standards/Approvals
- Standard Marks/Approvals United States, Canada, European Union (EU), Australia/New Zealand, Japan, China (PRC), Russia, Mexico, Germany, South Korea, Taiwan, India
- Safety Certifications UL 62368-1 | CAN/CSA-C22.2 No.62368-1- 19 | CE to EN 62368-1 |
- Emissions (EMC) CB IEC 62368-1 | Power Supplies CCC & BIS
- Harmonics & Flicker FCC CFR 47 Part 15 Subpart B Class A | ICES/NMB-003 Class A | EN 55032:2015 Class A |AS/NZS CISPR 22/CISPR 32 Class A | VCCI Class A | KN 32/KN 35 Class A | CNS 15936 Class A
- Immunity EN 61000-3-2 | EN 61000-3-3
- Environmental Standards EN 55032 | KN 32/KN 35
Redundant Power Supply Units
- Power Supply
- Ecodesign (Model 700-014575-0800) – Platinum
- Power efficiency: 230VAC50/Hz; 10% Load = >80%; 20% Load = >90%; 50% Load = >94%; 100% Load = >91%
- Power factor conditions (PFC): 50% Loading = >0.90
- Power Supply
- Ecodesign (Model SPASGAT-02) – Titanium
- Power Efficiency: 230VAC50/Hz; 10% Load = >90%; 20% Load = >94%; 50% Load = >96%; 100% Load = >91%
- Power factor conditions (PFC): 50% Loading = >0.95
Please note that although care has been taken in the degree of relevancy, pictures are for
display purposes only, and product appearance may differ from what you see. If there are any
discrepancies between the product headline, description and picture, the correct information
will be in the product headline (i.e. computer systems may not come with monitors even if
pictured that way). If anything is unclear, please email support before placing your order.