Feature
|
Cisco ASA 5505; Security Plus
|
Cisco ASA 5510; Security Plus
|
Cisco ASA 5512-X; Security Plus
|
Cisco ASA 5515-X
|
Stateful Inspection Throughput (Maximum1)
|
Up to 150 Mbps
|
Up to 300 Mbps
|
1 Gbps
|
1.2 Gbps
|
Stateful Inspection Throughput (Multiprotocol2)
|
-
|
-
|
500 Mbps
|
600 Mbps
|
IPS Throughput3
|
Up to 75 Mbps with AIP-SSC-5
|
Up to 150 Mbps with AIP-SSM-10
Up to 300 Mbps with AIP-SSM-20
|
250 Mbps
(Extra hardware not required)
|
400 Mpbs
(Extra hardware not required)
|
Next-Generation Throughput4 (Multiprotocol)
|
-
|
-
|
200 Mbps
|
350 Mbps
|
3DES/AES VPN Throughput5
|
Up to 100 Mbps
|
Up to 170 Mbps
|
200 Mbps
|
250 Mbps
|
Users/Nodes
|
Unlimited
|
Unlimited
|
Unlimited
|
Unlimited
|
IPsec VPN Peers
|
251
|
250
|
250
|
250
|
Cisco Cloud Web Security Users
|
25
|
75
|
100
|
250
|
Premium AnyConnect VPN Peers (Included/Maximum)
|
2/25
|
2/250
|
2/250
|
2/250
|
Concurrent Connections
|
10,000; 25,000*
|
50,000; 130,000*
|
100,000
|
250,000
|
New Connections/
Second
|
4000
|
9000
|
10,000
|
15,000
|
Virtual Interfaces (VLANs)
|
3 (trunking disabled)/
20 (trunking enabled)*
|
50; 100
|
50; 100
|
100
|
Security Contexts (Included/Maximum)6
|
Not available
|
0,0;
2,5
|
0,0;
2,5
|
2,5
|
High Availability
|
Not supported*
|
Not supported; Active/Active and Active/Standby**
|
Not supported; Active/Active and Active/Standby**
|
Active/Active and Active/Standby
|
Expansion Slot
|
1 SSC
|
1 SSM
|
1 interface card
|
1 interface card
|
User-Accessible Flash Slot
|
-
|
1
|
No
|
No
|
USB 2.0 Ports
|
3 (1 on front, 2 on rear)
|
2
|
2
|
2
|
Integrated I/O
|
8 Fast Ethernet with 2 PoE ports
|
5 Fast Ethernet/2 GE Copper, 3 Fast Ethernet
|
6 GE Copper
|
6 GE Copper
|
Expansion I/O
|
-
|
4 GE Copper or
4 GE SFP
|
6 GE Copper or
6 GE SFP
|
6 GE Copper or
6 GE SFP
|
Serial Ports
|
1 RJ-45 console
|
2 RJ-45, console and auxiliary
|
1 RJ-45 console
|
1 RJ-45 console
|
Solid State Drive
|
-
|
-
|
1 slot, 120 GB MLC SED
|
1 slot, 120 GB MLC SED
|
Memory
|
512 MB
|
1 GB
|
4 GB
|
8 GB
|
Minimum System Flash
|
128 MB
|
256 MB
|
4 GB
|
8 GB
|
System Bus
|
Multibus architecture
|
Multibus architecture
|
Multibus architecture
|
Multibus architecture
|
Operating
|
Temperature
|
32 to 104°F (0 to 40°C)
|
32 to 104°F (0 to 40°C)
|
23 to 104°F (-5 to 40°C)
|
23 to 104°F (-5 to 40°C)
|
Relative Humidity
|
5 to 95 percent noncondensing
|
5 to 95 percent noncondensing
|
10 to 90 percent noncondensing
|
10 to 90 percent noncondensing
|
Altitude
|
Designed and tested for 0 to 9840 ft (3000m); agency approved for 2000m
|
Designed and tested for 0 to 9840 ft (3000m); agency approved for 2000m
|
Designed and tested for 0 to 15,000 ft (4572m)
|
Designed and tested for 0 to 15,000 ft (4572m)
|
Shock
|
1.14 m/sec (45 in./sec) 1/2 sine input
|
1.14 m/sec (45 in./sec) 1/2 sine input
|
70G, 4.22 m/sec
|
70G, 4.22 m/sec
|
Vibration
|
0.41 Grms2 (3 to 500 Hz) random input
|
0.41 Grms2 (3 to 500 Hz) random input
|
0.41 Grms2 (3 to 500 Hz) random input
|
0.41 Grms2 (3 to 500 Hz) random input
|
Acoustic Noise
|
60 dBa max
|
60 dBa max
|
64.2 dBa max
|
64.2 dBa max
|
Nonoperating
|
Temperature
|
-13 to 158ºF (-25 to 70ºC)
|
-13 to 158ºF (-25 to 70ºC)
|
-13 to 158ºF (-25 to 70ºC)
|
-13 to 158ºF (-25 to 70ºC)
|
Relative Humidity
|
5 to 95 percent noncondensing
|
5 to 95 percent noncondensing
|
10 to 90 percent noncondensing
|
10 to 90 percent noncondensing
|
Altitude
|
0 to 15,000 ft (4570m)
|
0 to 15,000 ft (4570m)
|
Designed and tested for 0 to 15,000 ft (4570m)
|
Designed and tested for 0 to 15,000 ft (4570m)
|
Shock
|
30G
|
30G
|
70G, 4.22 m/sec
|
70G, 4.22 m/sec
|
Vibration
|
0.41 Grms2 (3 to 500 Hz) random input
|
0.41 Grms2 (3 to 500 Hz) random input
|
1.12 Grms2 (3 to 500 Hz) random input
|
1.12 Grms2 (3 to 500 Hz) random input
|
Power
|
Input (per Power Supply)
|
AC Range Line Voltage
|
100 to 240 VAC
|
100 to 240 VAC
|
100 to 240 VAC
|
100 to 240 VAC
|
AC Normal Line Voltage
|
100 to 240 VAC
|
100 to 240 VAC
|
100 to 240 VAC
|
100 to 240 VAC
|
AC Current
|
1.8A
|
3A
|
4.85A
|
4.85A
|
AC Frequency
|
50/60 Hz
|
47/63 Hz
|
50/60 Hz
|
50/60 Hz
|
Dual-Power Supplies
|
None
|
None
|
None
|
None
|
DC Domestic Line Voltage
|
See the ASA 5500 Series Hardware Installation Guide
|
See the ASA 5500 Series Hardware Installation Guide
|
-40.5 to 56 VDC (-48 VDC nominal)
|
-40.5 to 56 VDC (-48 VDC nominal)
|
DC International Line Voltage
|
See the ASA 5500 Series Hardware Installation Guide
|
See the ASA 5500 Series Hardware Installation Guide
|
-55 to -72 VDC
(-60 VDC nominal)
|
-55 to -72 VDC
(-60 VDC nominal)
|
DC Current
|
See the ASA 5500 Series Hardware Installation Guide
|
See the ASA 5500 Series Hardware Installation Guide
|
15A (maximum input)
|
15A (maximum input)
|
Output
|
Steady State
|
20W
|
150W
|
51W
|
65W
|
Maximum Peak
|
96W
|
190W
|
56W
|
70W
|
Maximum Heat Dissipation
|
72 BTU/hr
|
648 BTU/hr
|
192 BTU/hr
|
239 BTU/hr
|
Form Factor
|
Desktop
|
1 RU, 19-in. rack-mountable
|
1 RU, 19-in. rack-mountable
|
1 RU, 19-in. rack-mountable
|
Dimensions (H x W x D)
|
1.75 x 7.89 x 6.87 in. (4.45 x 20.04 x 17.45 cm)
|
1.75 x 17.5 x 14.25 in. (4.45 x 20.04 x 36.20 cm)
|
1.67 x 16.7 x 15.6 In (4.24 x 42.9 x 39.5 cm)
|
1.67 x 16.7 x 15.6 In (4.24 x 42.9 x 39.5 cm)
|
Weight (with AC Power Supply)
|
4.0 lb (1.8 kg)
|
20.0 lb (9.07 kg)
|
13.39 lb (6.07 kg)
|
13.39 lb (6.07 kg)
|
Safety
|
UL 60950, CSA C22.2 No. 60950, EN 60950 IEC 60950, AS/NZS60950
|
UL 60950, CSA C22.2 No. 60950, EN 60950 IEC 60950, AS/NZS60950
|
IEC 60950-1: 2005, 2nd Edition
EN 60950-1:2006+A11: 2009
UL 60950-1:2007, 2nd Edition;
CSA C22.2 No. 60950-1-07, 2nd Edition
|
IEC 60950-1: 2005, 2nd Edition
EN 60950-1:2006+A11: 2009
UL 60950-1:2007, 2nd Edition;
CSA C22.2 No. 60950-1-07, 2nd Edition
|
Electromagnetic Compatibility (EMC)
|
CE marking, FCC Part 15 Class B, AS/NZS CISPR22 Class B, VCCI Class B, EN55022 Class B, CISPR22 Class B, EN61000-3-2,
EN61000-3-3
|
CE marking, FCC Part 15 Class A, AS/NZS CISPR22 Class A, VCCI Class A, EN55022 Class A, CISPR22 Class A, EN61000-3-2,
EN61000-3-3
|
CE: EN55022 2006+A1: 2007 Class A; EN55024 1998+A1:2001+A2:2003; EN61000-3-2 2009; EN61000-3-3 2008;
FCC: CFR 47, Part 15 Subpart B Class A 2010, ANSI C63.4 2009;
ICES-003 ISSUE 4 FEBRUARY.2004;
VCCI: V-3/2011.04;
C-TICK: AS/NZS CISPR 22,2009
KC: KN22 & KN24
|
CE: EN55022 2006+A1: 2007 Class A; EN55024 1998+A1: 2001+A2:2003; EN61000-3-2 2009; EN61000-3-3 2008;
FCC: CFR 47, Part 15 Subpart B Class A 2010, ANSI C63.4 2009;
ICES-003 ISSUE 4 FEBRUARY.2004;
VCCI: V-3/2011.04;
C-TICK: AS/NZS CISPR 22,2009
KC: KN22 & KN24
|
Industry Certifications
|
FIPS 140-2 Level 2
In process: Common Criteria EAL4+ US DoD Application-Level Firewall for Medium-Robustness Environments, and Common Criteria EAL4 for IPsec/SSL VPN
|
Common Criteria EAL4 US DoD Application-Level Firewall for Medium-Robustness Environments, Common Criteria EAL2 for IPS on AIP SSM-10 and -20, FIPS 140-2 Level 2, and NEBS Level 3
In process: Common Criteria EAL4+ US DoD Application-Level Firewall for Medium-Robustness Environments, and Common Criteria EAL4 for IPsec/SSL VPN
|
In process
|